Logo Image Access
Bookeye® 4 Semiautom.

Bookeye® 4 V2 Semiautomatic Book Scanner - Technical Data

This section provides you with the technical specifications and data associated with the Bookeye® 4 V2 Semiautomatic book scanner. Speed, scan size, power consumption and environmental data can be found as well as shipping dimensions and weight. These documents are the most detailed summary of the technical specifications.

BE4-SGS-V2Semiautomatic

Bookeye® 4 V2 Semiautomatic Book Scanner - Technical Data

Document
Maximum Document Size460 x 620 mm (18 x 24.4 inches),
14% > DIN A2
Output
Scanner Resolution600 x 600 dpi
Pixel Dimension 9.3 x 9.3 µm
Scan Speed ColorDIN A2+ @ 150 dpi: 0.9 s
DIN A2+ @ 200 dpi: 1.1 s
DIN A2+ @ 300 dpi: 1.6 s
DIN A2+ @ 400 dpi: 2.0 s
DIN A2+ @ 600 dpi: 3.0 s
Color Depth48 bit color, 16 bit grayscale
Scan Output24 bit color, 8 bit grayscale, bitonal, enhanced halftone
File FormatsMultipage PDF (PDF/A) and TIFF, JPEG, JPEG 2000, PNM, PNG, BMP,
TIFF (Raw, G3, G4, LZW, JPEG), AutoCAD DWF, JBIG, DjVu,
DICOM, PCX, Postscript, EPS, Raw data
ICC ProfilesEmbedded for sRGB, Adobe RGB and native. Individual profiling via web based Scan2ICC subscription
QualityExceeds FADGI ** guidelines, ISO 19264-1
Technical Specifications
Computer64 bit Linux, Intel i3, quad core processor,
8 Gigabyte RAM, 320GB HDD for extra large jobs
Touchscreen7 inch color WVGA (wide VGA) touchscreen
Monitor22 inch touchscreen (optionally available)
USB Port2 USB Ports 3.0
Interface1 GBit Fast Ethernet with TCP/IP based Scan2Net® interface
CameraCCD camera
Light SourceWhite LEDs, tested according to IEC 62471, no IR/UV emission
Declaration about the Emission of UV and IR radiation
Lamp Lifetime50,000 h (typ.)
Dimensions
Dimensions Scanner
(H x W x D)
900 x 880 x 860 mm (35.4 x 34.6 x 33.9 inches)
Weight Scanner109 kg (240 lbs.)
Electrical Specifications
Electrical Connection100-240 V AC, 47 - 63 Hz (external power supply,
complies with ECO standard CEC level VI)
Power Consumption16.5 W (Standby) / < 75 W (Ready to scan) / 150 W (Scanning) / 150 W (Fully automatic scan cycle)
Ambient Conditions
Operating Temp5 to 40 °C (40 to 105 °F)
Rel Humidity20 to 80 % (non-condensing)
Noise< 56 dB(A) (Fully automatic scan cycle) / < 40 dB(A) (Scanning) / < 33 dB(A) (Standby)

Technical changes, errors and omissions excepted. All information subject to change.